Here, a data logger in the attic of House 5 records measurements like temperature, relative humidity, and electricity consumption taken from sensors located throughout the house.

IBACOS conducts long-term monitoring of houses as a major part of our research work. Over the course of one to three years, monitoring equipment measures the performance of a house, as well as the performance of specific building technologies in the house, such as the HVAC system and the domestic hot water (DHW) system. IBACOS observes the interactions among the various systems, particularly those interactions that are difficult to determine through modeling. Below, download recent data (Microsoft Excel as comma seperated values) obtained from the houses that IBACOS is currently monitoring or has recently completed monitoring.

Houses 1 and 2

Houses 1 and 2 are located in central Kansas. The measurements from these two houses include:

  • Water heater performance: Natural gas use, temperature and volume of cold water entering and hot water supplied by the water heater
  • HVAC system performance: Furnace natural gas use, air conditioner outdoor unit compressor and fan electricity use, air handler unit fan electricity use, temperature and relative humidity (RH) at the first floor thermostat
  • Outdoor environment: Temperature and RH

Download monitoring data: House 1, House 2

House 3

House 3 is located in central Illinois. The measurements from this house include:

  • Indoor comfort conditions: Temperature and RH at several locations throughout the house
  • Outdoor environment: Temperature and RH
  • Electricity consumption: Whole house, space heating, DHW, and oven

Download monitoring data: House 3 (energy), House 3 (temperature and RH)

House 4

House 4 is located in central Illinois. The measurements from this house include:

  • Water heater performance: Tankless water heater electricity use, volume and temperature of cold water entering and hot water supplied by the electric tankless water heater
  • HVAC system performance: Heat pump electricity use and runtime, baseboard heat electricity use and runtime (individually), energy recovery ventilator (ERV) preheater electricity use and runtime, temperature and RH measurements on ERV airstreams
  • Indoor comfort conditions: Floor slab, temperature and RH in the master bedroom, bedroom #1 on the first floor facing southwest, bedroom #2 on the second floor facing southeast, bedroom #3 on the second floor facing northeast, bathroom #1 on the first floor, bathroom #2 on the second floor, thermostat location, stairwell below the heat pump
  • Outdoor environment: Air temperature and RH, incident solar radiation on the south wall
  • Electricity consumption: Whole house, major appliances, lighting, plug loads
  • Other measurements: Wall moisture content on the north, south, and east walls; clothes washer hot and cold water consumption; attic temperature and RH

Download monitoring data: House 4

Houses 5 and 6

Houses 5 and 6 are located in central Georgia. The measurements from these two houses include:

  • Water heater performance: Electricity used by electric resistance elements and by the desuperheater circulation pump, thermal energy harvested from the desuperheater and delivered to the house and fixtures
  • HVAC system performance: Coefficient of performance (COP) of the ground source heat pump, system electricity use and runtime, supply air temperature in plenum, return air temperature at the filter and central return, supply temperature at the end of the longest duct run, temperature and RH at the first and second floor thermostats
  • Outdoor environment: Temperature and RH
  • Electricity consumption: Whole house

Download monitoring data: House 5, House 6

House 7

House 7 is located in Denver, Colorado. The measurements from this house include:

  • Water heater performance: Tankless water heater natural gas use, tank-type water heater electricity use, volume and temperature of cold water entering and hot water leaving each water heater, volume of water recirculated by recirculation system
  • HVAC system performance: Furnace natural gas use, electricity use of the heat pump outdoor unit compressor and fan and air handler unit, temperature of fresh air entering furnace from the heat recovery ventilator (HRV), supply air temperature (SAT) in the plenum, longest and shortest runs in each zone, return air temperature at the filter and the return grille in each zone, temperature and RH at the first and second floor thermostats and in the master bedroom
  • Electricity consumption: Whole house, lighting and miscellaneous loads (grouped), appliances (grouped)
  • Photovoltaic array performance: Electricity produced, electricity sold to the grid, incident solar radiation on garage roof
  • Outdoor environment: Temperature and RH
  • Other measurements: Whole house natural gas consumption

Download monitoring data: House 7

House 8

House 8 is located in Orlando, Florida. The measurements from this house include the moisture content and temperature of the aerated concrete block.

Download monitoring data: House 8

House 9

House 9 is located in Las Vegas, Nevada. The measurements from this house include:

  • Water heater performance: Temperature of cold water entering and hot water leaving the water heater, temperature and volume of hot water entering the shower
  • HVAC system performance of the six mini-split air handler units located in the bedroom wing of the house: Runtime, supply air temperature, temperature and RH at the return air grill, temperature at the thermostat height
  • Outdoor environment: Temperature and RH of the outdoor air and sunken garden area; incident solar radiation on the east, south, and west walls

Download monitoring data: House 9

House 10

House 10 is located in Las Vegas, Nevada. The measurements from this house include:

  • HVAC system performance: Electricity use of the heat pump and AHU fan, temperature and RH at the first and second floor thermostats
  • Electricity consumption: Lighting, whole house
  • Photovoltaic array performance: Electricity produced, electricity sold to the grid, incident solar radiation on the roof
  • Outdoor environment: Temperature and RH
  • Other measurements: Electricity consumption of the lighting and whole house, photovoltaic electricity production, incident solar radiation

Download monitoring data: House 10